Date: Tue, 6 Apr 2010 10:21:25 -0400 (EDT)
From: Jun-Hui Zhao 
To: Ken Young 
Cc: Glen Petitpas , Raymond Blundell 
Subject: Re: SMA Data Reduction Software Meeting

A Miriad patch has been developed for fixing this problem.
http://www.cfa.harvard.edu/sma/miriad/download/QandA/smaPatch.html
Dan Marrone made a test with his data.
Here is the path for finding the pacth and usage for the
testing version:
http://www.cfa.harvard.edu/sma/miriad/minutes/drx2010/patch_usage.html
     Jun-Hui





On Tue, 6 Apr 2010, Ken Young wrote:

> On Mon, 5 Apr 2010, Glen Petitpas wrote:
>
> > I did find that the *current* version of MIRIAD (which worked last year)
> > will
> > no longer load _dual_receiver_ data. The smalod task complains about the
> > maximum number of baselines being exceeded.
>
> Yes - this was my fault.   The scans were being written twice.   The data
> is fine, just duplicated.   I have fixed that bug.
>
> Taco
>