[ Basic Info | References | User Guide ]

Basic Information on antpol


Task: antpol
Purpose: Calculate instrumental polarization from averaged uv-data.
Categories: uv analysis

ANTPOL - Calculate instrumental polarization from averaged uv-data.
ANTPOL does not apply the gains, bandpass, or polarization corrections.

Key: vis
The input UV dataset name. No default.

Key: select
This selects the data to be processed, using the standard uvselect
format. Default uses all the data.

Key: line
this gives the linetype that is used, in the
form:
  type,nchan,start,width,step
where type can be `channel' (default), `wide' or `velocity'.
Default is channel,1,1,1,1

Key: log
The list output file name. The default is the terminal.

User Guide References to antpol

[ Basic Info | References | User Guide ]

Generated by smamiriad@cfa.harvard.edu on 09 Jul 2012