UVCS MISSION LOG ---------------- Date: 06 January 2006 ----- Last revision: 10 January 2006 (Wu) -------------- File Name: 2006.01.08.a.log ---------- Compiled by: Y.-K. Ko, R. Wu ------------ UVCS Activity: Streamer Study for 06 - 09 January 2006 -------------- Load and Start OVI Synoptic for 09 January 2006 Load LyA Synoptic for 09 January 2006 SOHO Activity: -------------- EOF Staff: M. Uzzo: Lead Scientist, Planner ---------- Y.-K. Ko: Commander M. Uzzo: Commander R. Wu Command file: 06.01.06.19:09:46.cmd.log 06.01.08.18:50:43.cmd.log Activity: --------- 1) Streamer Properties Over the Solar Cycle Sequence: 06.01_StrObs.tcl, sw = 66 SCI_SPEC: A comprehensive study of several streamer properties including the outflow velocities, abundances, electron densities and temperatures. The spatial distribution of these physical properties are analyzed at multiple heights within several streamers examined over the course of the solar cycle. OBS_PROG: Primary: Spectral Resolution Sub Obj: Spatial Resolution SCI_OBJ: Primary: Coronal Dynamics...Outflow Velocities Sub Obj: Abundances OBJ: Streamer CMP_NAME: CMP_NUM: Duration: start: 2006.01.06.20:37 end: 2006.01.09.02:27 ONUMs = 22091 (40 exps) 22092 (160 exps) 22093 (240 exps) 22094 (160 exps) 22095 (240 exps) 22096 (240 exps) 22097 (240 exps) 22098 (239 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 232.5 Degrees (28329) - Mirror/Occulter: 1.75 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 50, 150 um - LYA GRTPOS: 100000 - OVI GRTPOS: 164600, 223500, 86600, 232100 - OVI MCP Voltage: 200 - OVI mask: OVI_str_164_225 in slot 6 msk_000303_OVI in slot 3 Fits Files: q06.01.06.20:36:06.ovi.dat q06.01.06.21:59:52.ovi.dat q06.01.07.03:31:37.ovi.dat q06.01.07.11:49:55.ovi.dat q06.01.07.17:21:37.ovi.dat q06.01.08.01:38:43.ovi.dat q06.01.08.09:54:43.ovi.dat q06.01.08.18:10:43.ovi.dat 2) OVI Synoptic Sequence Load and Start Sequence: SynopticD:Start SCI_SPEC: Synoptic studies. VLD & LYA HV & Power off / OVI voltage at 200. OBS_PROG: Synoptic SCI_OBJ: Synoptic OBJ: Entire Corona CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.02:42 end: 2006.01.09.16:56 ONUMs = 49320 (46 exps) 49321 (49 exps) 49322 (47 exps) 49323 (49 exps) 49324 (49 exps) 49325 (49 exps) 49326 (47 exps) 49327 (49 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: E: os, SE: os, S: oc, SW: os, W: os, NW: os, N: oc, SE: os - Mirror/Occulter: ls: 3.00, 2.50, 2.10, 1.90, 1.75, 1.60 Ro lc: 2.10, 1.90, 1.75, 1.60 Ro os: 3.00, 2.10, 1.90, 1.75, 1.60 Ro oc: 1.90, 1.75, 1.60 Ro ms: 2.10, 1.75, 1.60 Ro mc: 1.90, 1.75, 1.60 Ro 1.5 mm overocculting (1.60 Ro) 2.0 mm overocculting (1.75, 1.90, 2.10, 2.50, 3.00 Ro) - LYA Slits: 100 um - OVI Slits: 150 um (LyA Synoptic) 200 um (OVI, and Mini Synoptic) - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 (LyA Synoptic) 229000 (OVI, and Mini Synoptic) - OVI MCP Voltage: 200 - OVI mask: OVI_Syn_188 in slot 2 (LyA Synoptic) OVI_Syn_230 in slot 1 (OVI, and Mini Synoptic) Fits Files: z06.01.09.02:41:38.ovi.dat GAP between 01/09/06|02:58:44(11654) and 01/09/06|03:03:25(12100) z06.01.09.04:30:18.ovi.dat z06.01.09.06:18:59.ovi.dat z06.01.09.08:02:27.ovi.dat z06.01.09.09:51:07.ovi.dat z06.01.09.11:39:47.ovi.dat z06.01.09.13:28:27.ovi.dat z06.01.09.15:11:54.ovi.dat 3) LyA Synoptic Sequence Load and Start Sequence: SynopticD:Start SCI_SPEC: Synoptic studies. VLD & LYA HV & Power off / OVI voltage at 200. LyA Synoptic flushed to ramp down OVI Detector and perform Stimulus Pulse test using a new full detector mask. Flushed roll position scan allowed to finish, remaining roll position scans reloaded following test. OBS_PROG: Synoptic SCI_OBJ: Synoptic OBJ: Entire Corona CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.16:58 end: 2006.01.09.19:40 ONUMs = 49330 (18 exps) 49331 (34 exps) 49332 (18 exps) ; flushed Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: NE: ls, N: lc, NW: ls - Mirror/Occulter: ls: 3.00, 2.50, 2.10, 1.90, 1.75, 1.60 Ro lc: 2.10, 1.90, 1.75, 1.60 Ro os: 3.00, 2.10, 1.90, 1.75, 1.60 Ro oc: 1.90, 1.75, 1.60 Ro ms: 2.10, 1.75, 1.60 Ro mc: 1.90, 1.75, 1.60 Ro 1.5 mm overocculting (1.60 Ro) 2.0 mm overocculting (1.75, 1.90, 2.10, 2.50, 3.00 Ro) - LYA Slits: 100 um - OVI Slits: 150 um (LyA Synoptic) 200 um (OVI, and Mini Synoptic) - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 (LyA Synoptic) 229000 (OVI, and Mini Synoptic) - OVI MCP Voltage: 200 - OVI mask: OVI_Syn_188 in slot 2 (LyA Synoptic) OVI_Syn_230 in slot 1 (OVI, and Mini Synoptic) Fits Files: z06.01.09.16:57:31.ovi.dat z06.01.09.17:42:39.ovi.dat z06.01.09.18:59:47.ovi.dat 4) UVCS OVI Stimulus Pulse Test Sequence: Manual SCI_SPEC: OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.20:19 end: 2006.01.09.20:29 ONUMs = 22100 (2 exps) Instrument configuration: - Pointing: Sun Center - Spacecraft Roll: 180 Degrees - Roll: 270 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 150 um - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 - LYA HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - OVI mask: OVI_chk_1xfull in OVI slot 3 Fits Files: q06.01.09.20:18:36.ovi.dat 5) LyA Synoptic Sequence Load and Start Sequence: SynopticD:Start SCI_SPEC: Synoptic studies. VLD & LYA HV & Power off / OVI voltage at 200. LyA Synoptic flushed to ramp down OVI Detector and perform Stimulus Pulse test using a new full detector mask. Flushed roll position scan allowed to finish, remaining roll position scans reloaded following test. OBS_PROG: Synoptic SCI_OBJ: Synoptic OBJ: Entire Corona CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.20:41 end: 2006.01.10.00:53 ONUMs = 49333 (18 exps) ; reloaded 49334 (18 exps) ; reloaded 49335 (34 exps) ; reloaded 49336 (17 exps) ; reloaded 49337 (18 exps) ; reloaded Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: W: ls, SW: ls, S: lc, SE: ls, E: ls - Mirror/Occulter: ls: 3.00, 2.50, 2.10, 1.90, 1.75, 1.60 Ro lc: 2.10, 1.90, 1.75, 1.60 Ro os: 3.00, 2.10, 1.90, 1.75, 1.60 Ro oc: 1.90, 1.75, 1.60 Ro ms: 2.10, 1.75, 1.60 Ro mc: 1.90, 1.75, 1.60 Ro 1.5 mm overocculting (1.60 Ro) 2.0 mm overocculting (1.75, 1.90, 2.10, 2.50, 3.00 Ro) - LYA Slits: 100 um - OVI Slits: 150 um (LyA Synoptic) 200 um (OVI, and Mini Synoptic) - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 (LyA Synoptic) 229000 (OVI, and Mini Synoptic) - OVI MCP Voltage: 200 - OVI mask: OVI_Syn_188 in slot 2 (LyA Synoptic) OVI_Syn_230 in slot 1 (OVI, and Mini Synoptic) Fits Files: z06.01.09.20:40:28.ovi.dat z06.01.09.21:25:36.ovi.dat z06.01.09.22:10:44.ovi.dat z06.01.09.23:27:52.ovi.dat z06.01.10.00:12:59.ovi.dat