UVCS MISSION LOG ---------------- Date: 10 January 2006 ----- Last revision: 10 January 2006 (MU) -------------- File Name: 2006.01.09.a.log ---------- Compiled by: M. Uzzo ------------ UVCS Activity: Flush LyA Synoptic for 09 January 2006 -------------- Load Masks OVI_chk_1xfull in slot 3 OVI_chk_1x1 in slot 6 Run Diagnostic stim pulse test for 09 January 2006 Reload remaining LyA Synoptic for 09-10 January 2006 Load OVI Detector Diagnostic Full detector mask for 10 January 2006 SOHO Activity: -------------- EOF Staff: L. Gardner: Lead Scientist ---------- M. Uzzo: Commander, Planner R. Wu Command file: 06.01.09.19:26:12.cmd.log Activity: --------- 1) UVCS OVI Stimulus Pulse Test Sequence: Manual SCI_SPEC: OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.20:19 end: 2006.01.09.20:29 ONUMs = 22100 (2 exps) Instrument configuration: - Pointing: Sun Center - Spacecraft Roll: 180 Degrees - Roll: 270 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 150 um - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 - LYA HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - OVI mask: OVI_chk_1xfull in OVI slot 3 Fits Files: q06.01.09.20:18:36.ovi.dat 2) LyA Synoptic Sequence Load and Start Sequence: SynopticD:Start SCI_SPEC: Synoptic studies. VLD & LYA HV & Power off / OVI voltage at 200. LyA Synoptic flushed to ramp down OVI Detector and perform Stimulus Pulse test using a new full detector mask. Flushed roll position scan allowed to finish, remaining roll position scans reloaded following test. OBS_PROG: Synoptic SCI_OBJ: Synoptic OBJ: Entire Corona CMP_NAME: CMP_NUM: Duration: start: 2006.01.09.20:41 end: 2006.01.10.00:53 ONUMs = 49333 (18 exps) ; reloaded 49334 (18 exps) ; reloaded 49335 (34 exps) ; reloaded 49336 (17 exps) ; reloaded 49337 (18 exps) ; reloaded Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: W: ls, SW: ls, S: lc, SE: ls, E: ls - Mirror/Occulter: ls: 3.00, 2.50, 2.10, 1.90, 1.75, 1.60 Ro lc: 2.10, 1.90, 1.75, 1.60 Ro os: 3.00, 2.10, 1.90, 1.75, 1.60 Ro oc: 1.90, 1.75, 1.60 Ro ms: 2.10, 1.75, 1.60 Ro mc: 1.90, 1.75, 1.60 Ro 1.5 mm overocculting (1.60 Ro) 2.0 mm overocculting (1.75, 1.90, 2.10, 2.50, 3.00 Ro) - LYA Slits: 100 um - OVI Slits: 150 um (LyA Synoptic) 200 um (OVI, and Mini Synoptic) - LYA GRTPOS: 100000 - OVI GRTPOS: 187260 (LyA Synoptic) 229000 (OVI, and Mini Synoptic) - OVI MCP Voltage: 200 - OVI mask: OVI_Syn_188 in slot 2 (LyA Synoptic) OVI_Syn_230 in slot 1 (OVI, and Mini Synoptic) Fits Files: z06.01.09.20:40:28.ovi.dat z06.01.09.21:25:36.ovi.dat z06.01.09.22:10:44.ovi.dat z06.01.09.23:27:52.ovi.dat z06.01.10.00:12:59.ovi.dat 3) OVI Detector Diagnostic Sequence: Manual SCI_SPEC: OBS_PROG: Primary: Spatial Resolution SCI_OBJ: Primary: Instrument Diagnostics OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2006.01.10.0 end: 2006.01.10.1 ONUMs = 22101 ( exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 180.0 Degrees (18762) - Mirror/Occulter: 1.75 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 229000 - OVI MCP Voltage: 200 - OVI mask: OVI_chk_1xfull in slot 3 Fits Files: