UVCS MISSION LOG ---------------- Date: 21 August 2006 ----- Last revision: 06 September 2006 (Wu) -------------- File Name: 2006.09.05.a.log ---------- Compiled by: M. Uzzo, R. Wu ------------ UVCS Activity: UVCS in Modified Hard Safe Configuration -------------- SOHO Activity: Received via email Friday, 01 September 2006, -------------- 14:59:25 GMT: Last Update: 01 September 2006 15 UT Standard Disclaimer: All times are in UT and are estimates. Total Fuel Usage = 0.188 kg OCD (offpoint flag, SVM times, ESR flags) due 31 August 2006 SORR on 1 September 2006 at 1pm local time Limit violation sheets for safing due Tuesday 5 September 2006 Tuesday 05 September 2006 ------------------------- 17:00-20:45 D24 21:15-00:30 D43/D27 UVCS already safed SVM reserve time 17:00 18:00 LASCO safes 18:30 CDS safes CDS and LASCO removed from ESR flag warning list Wednesday 06 September 2006 --------------------------- 14:30-22:30 D24 22:15-00:05 D43/D46 SOC here by 14:00 UT CELIAS STOF safing using CEL_ESR_SAFE.DEL SWAN safed by FOT, remove SWAN from ESR warning flag list MDI loop opened by FOT with warning (~15 UT) Experiment offpoint flag function disabled SK then MM Burns should be complete by ~17 UT Experiment offpoint flags enabled for LASCO and MDI MDI loop closed by FOT after asking permission SWAN recovered by FOT, return SWAN to ESR warning flag list - 2 hours after last burn, then do recovery load CELIAS STOF recovery 6 hours after last burn using CEL11_RECOVR.DEL EOF Staff: R. Wu: Lead Scientist ---------- Y.-K. Ko M. Uzzo Command file: No Commanding Activity: --------- 1) UVCS in Modified Hard Safe Configuration Sequence: None SCI_SPEC: Following completion of Science Observations, UVCS is placed into a modified Hard Safe configuration in preparation for the SOHO High Gain Antenna Keyhole Period of September 2006. OVI and LyA Slits are set to 100 and 75 microns, instrument is rolled to nominal East (35156 Engineering Units). Detector High Voltage is ramped down and then turned off. The Mirror is moved to 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is also closed 708 steps, Internal Mirror / Occulter Heater set to 100% duty cycle (64). FOT using ESR Limit Set, TSU Substitution Heater (Circuit #84) powered on and set to 50% duty cycle. UVCS removed from Experiment Offpoint and ESR warning lists for Keyhole. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.09.05.16:00 end: 2006.09.06.16:00 ONUMs = 22721 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 270 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 75 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 210000 - LYA HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - LYA mask: LYA_100_8x2 in slot 2 - OVI mask: OVI_chk_1xfull in slot 6 Fits Files: GAP between 09/05/06|06:09:35(15887) and 09/05/06|17:03:11(13140) GAP between 09/05/06|20:44:39( 1655) and 09/05/06|21:18:44( 4923) GAP between 09/06/06|00:29:43( 6895) and 09/06/06|14:33:02( 5995)