UVCS MISSION LOG ---------------- Date: 21 August 2006 ----- Last revision: 19 September 2006 (Wu) -------------- File Name: 2006.09.18.a.log ---------- Compiled by: M. Uzzo, R. Wu ------------ UVCS Activity: Recover UVCS from Modified Hard Safe Configuration -------------- into Soft Safe Configuration Conduct LyA Stimulus Pulse Test Thermal Equilibration of UVCS in Soft Safe Configuration SOHO Activity: -------------- EOF Staff: M. P. Miralles: Lead Scientist ---------- M. Uzzo: Commander, Planner R. Wu Command file: 06.09.18.14:55:49.cmd.log Activity: --------- 1) Recover UVCS from Modified Hard Safe Configuration Sequence: Manual SCI_SPEC: UVCS is recovered from Hard Safe Configuration into a Soft Safe configuration in order to allow UVCS temperatures to return to nominal. Detector High Voltage remains ramped down and turned off instrument is rolled to nominal East (35156 Engineering Units). The Mirror stays at 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is opened at this time, Internal Mirror / Occulter Heater set to 0% duty cycle (255). OVI Detecor Timing and Charge Thresholds set. FOT told to continue to use UVCS ESR Limit Set. FOT component of UVCS recovery, including enabling of the ESR Warning Flags and Experiment Offpoint, completed at approximately 2054 and 2101 UT, respectively. TSU Substitution Heater (Circuit #84) OFF at 2108 UT Note: Recovery times (below) are approximate. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.09.18.20:54 end: 2006.09.18.21:19 ONUMs = 22721 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 90 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 75 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 210000 - LYA HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - LYA mask: LYA_100_8x2 in slot 2 - OVI mask: OVI_chk_1xfull in slot 6 Fits Files: 2) OVI Stimulus Pulse Test Sequence: TakeUV_TxN.tcl SCI_SPEC: OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.09.18.21:26 end: 2006.09.18.21:30 ONUMs = 22722 (2 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 90 degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 75 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 210000 - LYA MCP Voltage: 0 - OVI MCP Voltage: 0 - OVI mask: msk_000303_OVI in slot 3 Fits Files: q06.09.18.21:25:33.ovi.dat 3) Thermal Equilibration of UVCS in Soft Safe Configuration Sequence: none SCI_SPEC: UVCS is recovered from Hard Safe Configuration into a Soft Safe configuration in order to allow UVCS temperatures to return to nominal. Detector High Voltage remains ramped down and turned off. Instrument is rolled to the nominal West (35156 Engineering Units), and Mirror / Occulter is set at 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is open. Internal Mirror / Occulter Heater set to 0% duty cycle. FOT told to continue to use UVCS ESR Limit Table. Expected Limit Violation sheets submitted to FOT via SOC for any expected limit violations during this time. FOT component of UVCS recovery, including enabling of the ESR Warning Flags and Experiment Offpoint, completed at approximately 2054 and 2101 UT, respectively. TSU Substitution Heater (Circuit #84) OFF at 2108 UT OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2006.09.18.21:30 end: 2006.09.19.15:08 ONUMs = 22722 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 90 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 75 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 210000 - LYA HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - LYA DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - OVI mask: msk_000303_OVI in slot 3 Fits Files: