UVCS MISSION LOG ---------------- Date: 04 June 2007 ----- Last revision: 04 June 2007 (MU) -------------- File Name: 2007.06.04.a.log ---------- Compiled by: M. Uzzo ------------ UVCS Activity: Recover UVCS from Modified Hard Safe Configuration -------------- into Soft Safe Configuration Conduct LyA Stimulus Pulse Test Load Masks: LYA_303_8x2 in slot 3 StarFF_8x4_LYA in slot 2 Star_4x2_LYA in slot 4 Thermal Equilibration of UVCS in Soft Safe Configuration SOHO Activity: -------------- EOF Staff: M. Uzzo: Lead Scientist ---------- M. Uzzo: Commander, Planner Y.-K. Ko Command file: 07.06.04.11:40:40.cmd.log Activity: --------- 1) Recover UVCS from Modified Hard Safe Configuration Sequence: Manual SCI_SPEC: UVCS is recovered from Hard Safe Configuration into a Soft Safe configuration in order to allow UVCS temperatures to return to nominal. Detector High Voltage remains ramped down and turned off instrument is rolled to nominal East (35156 Engineering Units). The Mirror stays at 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is opened at this time, Internal Mirror / Occulter Heater set to 0% duty cycle (255). OVI Detecor Timing and Charge Thresholds set. FOT told to continue to use UVCS ESR Limit Set. FOT component of UVCS recovery, including enabling of the ESR Warning Flags and Experiment Offpoint, and the TSU Substitution Heater (Circuit #84) OFF at ~11:42 UT Note: Recovery times (below) are approximate. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2007.06.04.11:30 end: 2007.06.04.1 ONUMs = 23390 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 270 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 164600 - LYA HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - LYA DETECTOR POWERED ON - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - LYA mask: None Fits Files: 2) LyA Stimulus Pulse Test Sequence: TakeUV_TxN.tcl SCI_SPEC: OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2007.06.04.1 end: 2007.06.04.1 ONUMs = 23391 (2 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 270 degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 164600 - LYA MCP Voltage: 0 - OVI MCP Voltage: 0 - LYA mask: LYA_303_8x2 in slot 3 Fits Files: 3) Thermal Equilibration of UVCS in Soft Safe Configuration Sequence: none SCI_SPEC: UVCS is recovered from Hard Safe Configuration into a Soft Safe configuration in order to allow UVCS temperatures to return to nominal. Detector High Voltage remains ramped down and turned off. Instrument is rolled to the nominal East (35156 Engineering Units), and Mirror / Occulter is set at 1.5 Solar Radii with 1.5 mm overocculting. UVCS Aperture Door is open. Internal Mirror / Occulter Heater set to 0% duty cycle. FOT told to continue to use UVCS ESR Limit Table. Expected Limit Violation sheets submitted to FOT via SOC for any expected limit violations during this time. FOT component of UVCS recovery, including enabling of the ESR Warning Flags and Experiment Offpoint, and the TSU Substitution Heater (Circuit #84) OFF at ~11:42 UT OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2007.06.04.1 end: 2007.06.05.1 ONUMs = 23391 Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 270 Degrees (35156) - Mirror/Occulter: 1.5 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 100 um - LYA GRTPOS: 100000 - OVI GRTPOS: 164600 - LYA HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - VLD HIGH VOLTAGE RAMPED DOWN AND POWERED OFF - OVI DETECTOR POWERED OFF - VLD DETECTOR POWERED OFF - LYA mask: LYA_303_8x2 in slot 3 Fits Files: