UVCS MISSION LOG ---------------- Date: 24 August 2009 ----- Last revision: 27 August 2009 (Wu) -------------- File Name: 2009.08.24.a.log ---------- Compiled by: M. Uzzo, R. Wu ------------ UVCS Activity: Flush and Abort Coronal Hole Detector Background Study for -------------- 22 - 24 August 2009 Load embeded routine U_ExpLYAonly:TakeSet 1 6 id=2121.fxprm=22298 Load and Start OVI Detector Rate Diagnostic for 24 August 2009 Load Coronal Hole Detector Background Study for 24 - 26 August 2009 SOHO Activity: -------------- EOF Staff: J. Kohl: Lead Scientist ---------- M. Uzzo: Commander, Planner R. Wu Command file: 09.08.24.12:58:08.cmd.log Activity: --------- 1) OVI Detector Dark Rate Diagnostic Sequence: OVI_dark_chk.tcl SCI_SPEC: Determine Dark count rate for OVI detector. Instrument rolled to coronal hole, 5.0 Ro with 0.8 mm exposed mirror. Script engages OVI filter and then disengages it at end. OBS_PROG: Calibration SCI_OBJ: Calibration OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2009.08.24.15:22 end: 2009.08.24.16:23 ONUMs = 25707 (12 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 0 Degrees (18762) - Mirror/Occulter: 5.0 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 50 um - LYA GRTPOS: 100000 - OVI GRTPOS: 210000 - OVI Filter Engaged - OVI MCP Voltage: 205 - OVI mask: OVI_chk_1xfull in slot 6 Fits Files: q09.08.24.15:22:01.ovi.dat 2) Coronal Hole Detector Background Study Sequence: 09.08_hole_BG.tcl, n=17 , m=0 , r=0 , e=0 SCI_SPEC: Determine the dark background of the OVI detector to provide correction for the coronal hole study. OBS_PROG: Primary: Spectral Resolution Sub_Obj: Calibration SCI_OBJ: Calibration...Instrument Profile OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2009.08.24.16:25 end: 2009.08.26.15:15 ONUMs = 25708 (320 exps) 25709 (319 exps) 25710 (317 exps) 25711 (318 exps) 25712 (80 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: 0 Degrees (18762) - Mirror/Occulter: 5.0 Ro 2.37 mm exposed mirror - LYA Slit: 100 um - OVI Slit: 50 um - LYA GRTPOS: 100000 - OVI GRTPOS: 232100 - OVI Filter Engaged - OVI MCP Voltage: 205 - OVI mask: OVI_Hole_BG in slot 1 Fits Files: q09.08.24.16:24:44.ovi.dat q09.08.25.03:26:04.ovi.dat q09.08.25.14:27:24.ovi.dat GAP between 08/25/09|20:46:14( 6770) and 08/25/09|20:48:12( 6961) GAP between 08/25/09|21:24:17(10428) and 08/25/09|21:27:00(10691) q09.08.26.01:28:44.ovi.dat q09.08.26.12:30:04.ovi.dat