UVCS MISSION LOG ---------------- Date: 28 June 2010 ----- Last revision: 29 March 2010 (RR) -------------- File Name: 2010.06.28.a.log ---------- Compiled by: R. Rosati ------------ UVCS Activity: Ramp down and turn off LyA detector -------------- Turn on and ramp up OVI detector Conduct OVI Stimulus Pulse Test Conduct OVI detector dark rate diagnostic SOHO Activity: -------------- EOF Staff: L. Strachan: Lead Scientist ---------- R. Rosati: Commander Command file: 10.06.28.16:37:49.cmd.log Activity: --------- 1) LyA detector ramped down and turned off Sequence: Manual SCI_SPEC: Following completion of the third LyA component of the synoptic observation, the LyA MCP is ramped down and turned off. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2010.06.28.12:12 end: 2010.06.28.12:21 ONUMs = Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: -90 Degrees (51551) - Mirror/Occulter: 5.0 Ro 0.8 mm exposed mirror - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 67000 - OVI GRTPOS: 232100 - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - LYA mask: Fits Files: 2) OVI detector turn on, OVI Stimulus Pulse Test conducted, HV ramped up Sequence: Manual, TakeOVI_TxN 120 2 SCI_SPEC: After switching off LyA detector, the OVI detector is turned on a stimulus pulse test is completed After powering on OVI detector, discriminator settings were discovered to be incorrect. Discriminator settings were commanded to their nominal values. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2010.06.28.12:26 end: 2010.06.28.12:30 ONUMs = 26469 (2 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: -90 Degrees (51551) - Mirror/Occulter: 5.0 Ro 0.8 mm exposed mirror - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 67000 - OVI GRTPOS: 232100 - OVI MCP Voltage: 0 - OVI mask: Fits Files: q10.06.28.16:24:42.ovi.dat 3) OVI Detector Dark Rate Diagnostic Sequence: OVI_dark_chk 26470 51551 SCI_SPEC: Determine Dark count rate for OVI detector. Instrument rolled to coronal hole, 5.0 Ro with 0.8 mm exposed mirror. Script engages OVI filter and then disengages it at end. OBS_PROG: Calibration SCI_OBJ: Calibration OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2010.06.28.15:31 end: 2010.06.28.16:32 ONUMs = 26470 (12 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: -90 Degrees (51551) - Mirror/Occulter: 5.0 Ro 0.8 mm exposed mirror - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 67000 - OVI GRTPOS: 232100 - OVI Filter Engaged - OVI MCP Voltage: 205 - OVI mask: OVI_chk_1xfull in slot 6 Fits Files: q10.06.28.19:31:21.ovi.dat