UVCS MISSION LOG ---------------- Date: 16 Oct 2010 ----- Last revision: 20 Apr 2011 (RR) -------------- File Name: 2010.10.16.a.log ---------- Compiled by: R. Rosati ------------ UVCS Activity: Canned Spica Calibration Observation on LYA -------------- Ramp down and turn off LyA detector Turn on and ramp up OVI detector Conduct OVI Stimulus Pulse Test SOHO Activity: -------------- EOF Staff: R. Rosati: Lead Scientist ---------- R. Rosati: Commander Command file: 10.10.16.16:47:32.cmd.log Activity: --------- 1) Spica Calibration Observation Sequence: Star_Can_LYA 26622 47935 38438 27668 3 0 1 1 0 0 Star_Can_LYA 26623 48132 38291 27898 3 0 1 1 0 0 Star_Can_LYA 26624 48330 37914 28127 3 0 1 1 0 0 SCI_SPEC: Star crossings at several mirror positions. OBS_PROG: Primary: Spectral Coverage Sub Obj: Calibration SCI_OBJ: Primary: Celestial Target...Star Sub Obj: Radiometric Calibration OBJ: Stars...Spica CMP_NAME: CMP_NUM: Duration: start: 2010.10.16.15:32 end: 2010.10.16.18:38 ONUMs = 26622 (28 exps) 26623 (28 exps) 26624 (28 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: -70.16 Degrees (47935) -71.24 Degrees (48132) -72.33 Degrees (48330) - Mirror/Occulter: 7.9, 7.8, 7.7 Ro 1.5 mm overocculting - LYA Slits: 100 um - OVI Slits: 75 um - LYA GRTPOS: 83040 - OVI GRTPOS: 96700 - LYA MCP Voltage: 210 - LYA mask: LYA_303_8x2 in slot 3 Fits Files: q10.10.16.19:31:48.lya.dat q10.10.16.20:34:56.lya.dat q10.10.16.21:40:03.lya.dat 2) LyA detector ramped down and turned off Sequence: Manual SCI_SPEC: Following completion of the LyA observations of the synoptic observation, the LyA MCP is ramped down and turned off. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2010.10.16.18:45 end: 2010.10.16.19:00 ONUMs = Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: -72.33 Degrees (48330) - Mirror/Occulter: 7.7 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 75 um - LYA GRTPOS: 83040 - OVI GRTPOS: 96700 - LYA DETECTOR POWERED OFF - OVI DETECTOR POWERED OFF - LYA mask: Fits Files: 3) OVI detector turn on, OVI Stimulus Pulse Test conducted, HV ramped up Sequence: Manual, TakeOVI_TxN 120 2 SCI_SPEC: After switching off LyA detector, the OVI detector is turned on a stimulus pulse test is completed After powering on OVI detector, discriminator settings were discovered to be incorrect. Discriminator settings were commanded to their nominal values. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2010.10.16.19:20 end: 2010.10.16.19:44 ONUMs = 26626 (2 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: -72.33 Degrees (48330) - Mirror/Occulter: 7.7 Ro 1.5 mm overocculting - LYA Slit: 100 um - OVI Slit: 75 um - LYA GRTPOS: 83040 - OVI GRTPOS: 96700 - OVI MCP Voltage: 0 - OVI mask: OVI_Hole_237 in slot 2 Fits Files: q10.10.16.23:38:48.ovi.dat