UVCS MISSION LOG ---------------- Date: 2 Nov 2010 ----- Last revision: 20 Apr 2011 (RR) -------------- File Name: 2010.11.02.a.log ---------- Compiled by: R. Rosati ------------ UVCS Activity: Turn off LyA detector completely after FOT soft-safed UVCS -------------- just prior to keyhole maneuvers Turn on and ramp up OVI detector Conduct OVI Stimulus Pulse Test Conduct OVI detector dark rate diagnostic SOHO Activity: -------------- EOF Staff: R. Rosati: Lead Scientist ---------- R. Rosati: Commander Command file: 10.11.02.15:58:02.cmd.log Activity: --------- 1) OVI detector turn on, OVI Stimulus Pulse Test conducted, HV ramped up Sequence: Manual, TakeOVI_TxN 120 2 SCI_SPEC: After LyA detector turned off completely, the OVI detector is turned on and a stimulus pulse test is completed After powering on OVI detector, discriminator settings were discovered to be incorrect. Discriminator settings were commanded to their nominal values. OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2010.11.02.11:17 end: 2010.11.02.11:21 ONUMs = 26644 (2 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: -160 Degrees (64300) - Mirror/Occulter: 7.7 Ro 1.5 mm overocculting - LYA Slit: 50 um - OVI Slit: 100 um - LYA GRTPOS: 83040 - OVI GRTPOS: 204380 - OVI MCP Voltage: 0 - OVI mask: OVI_Hole_237 in slot 2 Fits Files: q10.11.02.15:15:57.ovi.dat 2) OVI Detector Dark Rate Diagnostic Sequence: OVI_dark_chk 26645 51551 SCI_SPEC: Determine Dark count rate for OVI detector. Instrument rolled to coronal hole, 5.0 Ro with 0.8 mm exposed mirror. Script engages OVI filter and then disengages it at end. OBS_PROG: Calibration SCI_OBJ: Calibration OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2010.11.02.12:00 end: 2010.11.02.12:45 ONUMs = 26645 (9 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 0 Degrees - Roll: -90 Degrees (51551) - Mirror/Occulter: 5.0 Ro 0.8 mm exposed mirror - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 83040 - OVI GRTPOS: 210000 - OVI Filter Engaged - OVI MCP Voltage: 205 - OVI mask: OVI_chk_1xfull in slot 6 Fits Files: q10.11.02.16:00:00.ovi.dat