UVCS MISSION LOG ---------------- Date: 18 Jan 2012 ----- Last revision: 20 Jun 2012 (RR) -------------- File Name: 2012.01.18.a.log ---------- Compiled by: R. Rosati ------------ UVCS Activity: Recover UVCS from soft safe configuration -------------- Ramp up Lya detector HV Conduct LyA detector dark rate diagnostic SOHO Activity: -------------- EOF Staff: R. Rosati: Commander ---------- Command file: 12.04.13.22:42:44.cmd.log Activity: --------- 1) Ramped up Lya detector high voltage Sequence: Manual SCI_SPEC: HV ramped up OBS_PROG: SCI_OBJ: OBJ: CMP_NAME: CMP_NUM: Duration: start: 2012.04.13.20:30 end: 2012.04.13.20:45 ONUMs = Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 163.3 Degrees (5406) - Mirror/Occulter: 2.7 Ro 1.5 mm overocculting for mirror position of 2.5 Ro - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 83040 - OVI GRTPOS: 98000 - LyA MCP Voltage: 210 - LyA mask: Fits Files: 2) LyA Detector Dark Rate Diagnostic Sequence: LYA_dark_chk 27452 17965 SCI_SPEC: Determine Dark count rate for LyA detector. Instrument rolled to coronal hole, 5.0 Ro with 0.8 mm exposed mirror. Script engages LYA filter and then disengages it at end. OBS_PROG: Calibration SCI_OBJ: Calibration OBJ: Coronal Hole CMP_NAME: CMP_NUM: Duration: start: 2012.04.13.20:57 end: 2012.04.13.21:57 ONUMs = 27452 (11 exps) Instrument configuration: - Pointing: Sun center - Spacecraft Roll: 180 Degrees - Roll: 94.4 Degrees (17965) - Mirror/Occulter: 5.0 Ro 0.8 mm exposed mirror - LYA Slit: 50 um - OVI Slit: 50 um - LYA GRTPOS: 83040 - OVI GRTPOS: 98000 - LyA Filter Engaged - LyA MCP Voltage: 210 - LyA mask: LYA_chk_1xfull in slot 6 Fits Files: q12.04.13.20:56:34.lya.dat